SHENYANG, CHINA · INTERNATIONAL BUSINESSINDUSTRIAL SOLUTIONS · GLOBAL ENQUIRIESsunny@mettalfluxglobal.com
METTALFLUX — Industrial Solutions
PRODUCT EXPLORER

Drilling Fluid Testing Equipment

Rotational viscometers, density balances, aging ovens, filter presses and other drilling-fluid test references. Review current model data, utilities and test-method compatibility before selection.

JR Viscometer Sample Heater reference photographJR

JR Viscometer Sample Heater

Viscometer Sample Heater reference for drilling-fluid rheology. Characterise drilling-fluid flow behaviour using the specified rotational or shear measurement method. Review the published information below, then request the current configuration, documentation and quotation for JR.

Working temperature range to be confirmed

ZNN-D6II Six-Speed Rotational Viscometer reference photographZNN-D6II

ZNN-D6II Six-Speed Rotational Viscometer

Six-Speed Rotational Viscometer reference for drilling-fluid rheology. Characterise drilling-fluid flow behaviour using the specified rotational or shear measurement method. Review the published information below, then request the current configuration, documentation and quotation for ZNN-D6II.

Working temperature range to be confirmed

ZNN-D6SP Digital Six-Speed Rotational Viscometer reference photographZNN-D6SP

ZNN-D6SP Digital Six-Speed Rotational Viscometer

Digital Six-Speed Rotational Viscometer reference for drilling-fluid rheology. Characterise drilling-fluid flow behaviour using the specified rotational or shear measurement method. Review the published information below, then request the current configuration, documentation and quotation for ZNN-D6SP.

Working temperature range to be confirmed

ZNN-D6-12S Twelve-Speed Rotational Viscometer reference photographZNN-D6-12S

ZNN-D6-12S Twelve-Speed Rotational Viscometer

Twelve-Speed Rotational Viscometer reference for drilling-fluid rheology. Characterise drilling-fluid flow behaviour using the specified rotational or shear measurement method. Review the published information below, then request the current configuration, documentation and quotation for ZNN-D6-12S.

Working temperature range to be confirmed

ZNN-D12S Digital Twelve-Speed Rotational Viscometer reference photographZNN-D12S

ZNN-D12S Digital Twelve-Speed Rotational Viscometer

Digital Twelve-Speed Rotational Viscometer reference for drilling-fluid rheology. Characterise drilling-fluid flow behaviour using the specified rotational or shear measurement method. Review the published information below, then request the current configuration, documentation and quotation for ZNN-D12S.

Working temperature range to be confirmed

YM series Liquid Density Balance reference photographYM series

YM series Liquid Density Balance

Liquid Density Balance reference for fluid density. Measure a drilling-fluid or liquid sample density using the proposed instrument and sample preparation procedure. Review the published information below, then request the current configuration, documentation and quotation for YM series.

Working temperature range to be confirmed

XYM series Stainless Steel Liquid Density Balance reference photographXYM series

XYM series Stainless Steel Liquid Density Balance

Stainless Steel Liquid Density Balance reference for fluid density. Measure a drilling-fluid or liquid sample density using the proposed instrument and sample preparation procedure. Review the published information below, then request the current configuration, documentation and quotation for XYM series.

Working temperature range to be confirmed

YMS Digital Liquid Density Meter reference photographYMS

YMS Digital Liquid Density Meter

Digital Liquid Density Meter reference for fluid density. Measure a drilling-fluid or liquid sample density using the proposed instrument and sample preparation procedure. Review the published information below, then request the current configuration, documentation and quotation for YMS.

Working temperature range to be confirmed

YYM Pressurised Liquid Density Balance reference photographYYM

YYM Pressurised Liquid Density Balance

Pressurised Liquid Density Balance reference for fluid density. Measure a drilling-fluid or liquid sample density using the proposed instrument and sample preparation procedure. Review the published information below, then request the current configuration, documentation and quotation for YYM.

Working temperature range to be confirmed

DWY-2 Electrical Stability Tester reference photographDWY-2

DWY-2 Electrical Stability Tester

Electrical Stability Tester reference for electrical properties. Evaluate the electrical behaviour of a drilling-fluid sample under a defined measurement procedure. Review the published information below, then request the current configuration, documentation and quotation for DWY-2.

Working temperature range to be confirmed

DZL Drilling Fluid Resistivity Tester reference photographDZL

DZL Drilling Fluid Resistivity Tester

Drilling Fluid Resistivity Tester reference for electrical properties. Evaluate the electrical behaviour of a drilling-fluid sample under a defined measurement procedure. Review the published information below, then request the current configuration, documentation and quotation for DZL.

Working temperature range to be confirmed

GJ-3S Digital High-Speed Drilling Fluid Mixer reference photographGJ-3S

GJ-3S Digital High-Speed Drilling Fluid Mixer

Digital High-Speed Drilling Fluid Mixer reference for drilling-fluid preparation. Prepare and mix a drilling-fluid sample for laboratory or field evaluation. Review the published information below, then request the current configuration, documentation and quotation for GJ-3S.

Working temperature range to be confirmed

GRL-BX Portable Roller Oven reference photographGRL-BX

GRL-BX Portable Roller Oven

Portable Roller Oven reference for thermal aging. Condition drilling-fluid samples for comparison of formulation or additive performance. Review the published information below, then request the current configuration, documentation and quotation for GRL-BX.

Published operating temperature: 50–260°C

BGRL-5X Five-Roller Variable-Speed Aging Oven reference photographBGRL-5X

BGRL-5X Five-Roller Variable-Speed Aging Oven

Five-Roller Variable-Speed Aging Oven reference for thermal aging. Condition drilling-fluid samples for comparison of formulation or additive performance. Review the published information below, then request the current configuration, documentation and quotation for BGRL-5X.

Published operating temperature: 50–260°C

BGRL-7X Seven-Roller Variable-Speed Aging Oven reference photographBGRL-7X

BGRL-7X Seven-Roller Variable-Speed Aging Oven

Seven-Roller Variable-Speed Aging Oven reference for thermal aging. Condition drilling-fluid samples for comparison of formulation or additive performance. Review the published information below, then request the current configuration, documentation and quotation for BGRL-7X.

50–260°C in parameter table; conflicting narrative value to confirm

EP-2A Drilling Fluid Lubricity Tester reference photographEP-2A

EP-2A Drilling Fluid Lubricity Tester

Drilling Fluid Lubricity Tester reference for lubricity & adhesion. Compare drilling-fluid lubrication or filter-cake friction and adhesion under a defined test procedure. Review the published information below, then request the current configuration, documentation and quotation for EP-2A.

Working temperature range to be confirmed

ZNS-A Medium-Pressure Filter Press reference photographZNS-A

ZNS-A Medium-Pressure Filter Press

Medium-Pressure Filter Press reference for drilling-fluid filtration. Measure drilling-fluid filtration behaviour and review the resulting filter cake. Review the published information below, then request the current configuration, documentation and quotation for ZNS-A.

Working temperature range to be confirmed

ZNS-5A Medium-Pressure Filter Press reference photographZNS-5A

ZNS-5A Medium-Pressure Filter Press

Medium-Pressure Filter Press reference for drilling-fluid filtration. Measure drilling-fluid filtration behaviour and review the resulting filter cake. Review the published information below, then request the current configuration, documentation and quotation for ZNS-5A.

Working temperature range to be confirmed

GGS42-2 HPHT Drilling Fluid Filter Press reference photographGGS42-2

GGS42-2 HPHT Drilling Fluid Filter Press

HPHT Drilling Fluid Filter Press reference for drilling-fluid filtration. Measure drilling-fluid filtration behaviour and review the resulting filter cake. Review the published information below, then request the current configuration, documentation and quotation for GGS42-2.

Working temperature range to be confirmed

GGS71-2 HPHT Drilling Fluid Filter Press reference photographGGS71-2

GGS71-2 HPHT Drilling Fluid Filter Press

HPHT Drilling Fluid Filter Press reference for drilling-fluid filtration. Measure drilling-fluid filtration behaviour and review the resulting filter cake. Review the published information below, then request the current configuration, documentation and quotation for GGS71-2.

Published operating temperature: Ambient to 232°C

ZNH-1 Drilling Fluid Sand Content Kit reference photographZNH-1

ZNH-1 Drilling Fluid Sand Content Kit

Drilling Fluid Sand Content Kit reference for solids & inhibition. Evaluate sand, liquid/solid fractions or shale swelling using the method specified for this reference. Review the published information below, then request the current configuration, documentation and quotation for ZNH-1.

Working temperature range to be confirmed

NZ-3A Filter-Cake Friction Coefficient Tester reference photographNZ-3A

NZ-3A Filter-Cake Friction Coefficient Tester

Filter-Cake Friction Coefficient Tester reference for lubricity & adhesion. Compare drilling-fluid lubrication or filter-cake friction and adhesion under a defined test procedure. Review the published information below, then request the current configuration, documentation and quotation for NZ-3A.

Working temperature range to be confirmed

ZNG Drilling Fluid Retort Kit reference photographZNG

ZNG Drilling Fluid Retort Kit

Drilling Fluid Retort Kit reference for solids & inhibition. Evaluate sand, liquid/solid fractions or shale swelling using the method specified for this reference. Review the published information below, then request the current configuration, documentation and quotation for ZNG.

Working temperature range to be confirmed

ZNG-1A Oil / Water / Solids Retort reference photographZNG-1A

ZNG-1A Oil / Water / Solids Retort

Oil / Water / Solids Retort reference for solids & inhibition. Evaluate sand, liquid/solid fractions or shale swelling using the method specified for this reference. Review the published information below, then request the current configuration, documentation and quotation for ZNG-1A.

Working temperature range to be confirmed

NP-01 Shale Swelling Tester reference photographNP-01

NP-01 Shale Swelling Tester

Shale Swelling Tester reference for solids & inhibition. Evaluate sand, liquid/solid fractions or shale swelling using the method specified for this reference. Review the published information below, then request the current configuration, documentation and quotation for NP-01.

Working temperature range to be confirmed

QL Shearometer reference photographQL

QL Shearometer

Shearometer reference for drilling-fluid rheology. Characterise drilling-fluid flow behaviour using the specified rotational or shear measurement method. Review the published information below, then request the current configuration, documentation and quotation for QL.

Working temperature range to be confirmed

NF-2 Filter-Cake Adhesion Tester reference photographNF-2

NF-2 Filter-Cake Adhesion Tester

Filter-Cake Adhesion Tester reference for lubricity & adhesion. Compare drilling-fluid lubrication or filter-cake friction and adhesion under a defined test procedure. Review the published information below, then request the current configuration, documentation and quotation for NF-2.

Working temperature range to be confirmed

Missing model data is marked “to be confirmed”. Product-family illustrations and reference photographs are labelled. No certification, customer endorsement or conformity is implied.

Let’s start with your requirements.

Share your application, conditions and delivery country.

Discuss your project